COMPANY HEADER
Request Information
Unit of Measure
Items
Tubular-family

0.315 Inch (in) Heating Element Diameter, 20 Inch (in) Heated Length, and 500 Wattage (W) Incoloy® Sheathed Element Tubular Heater

Tubular-family

0.315 Inch (in) Heating Element Diameter, 22 Inch (in) Heated Length, and 500 Wattage (W) Incoloy® Sheathed Element Tubular Heater

Tubular-family

0.315 Inch (in) Heating Element Diameter, 24 Inch (in) Heated Length, and 600 Wattage (W) Incoloy® Sheathed Element Tubular Heater

Tubular-family

0.315 Inch (in) Heating Element Diameter, 26 Inch (in) Heated Length, and 700 Wattage (W) Incoloy® Sheathed Element Tubular Heater

Tubular-family

0.315 Inch (in) Heating Element Diameter, 28 Inch (in) Heated Length, and 700 Wattage (W) Incoloy® Sheathed Element Tubular Heater
Brands N/A WATTCO™
Heating Element Diameter N/A 0.315 in8.0 mm
Heated Length N/A 20 in508 mm N/A 22 in559 mm N/A 24 in610 mm N/A 26 in660 mm N/A 28 in711 mm
Wattage N/A 500 W N/A 500 W N/A 600 W N/A 700 W N/A 700 W
Voltage N/A 120 V208 V240 V
Power Density N/A 25 W/in²3.9 W/cm² N/A 23 W/in²3.6 W/cm² N/A 25 W/in²3.9 W/cm² N/A 27 W/in²4.2 W/cm² N/A 25 W/in²3.9 W/cm²
Current at 120 Volt (V) Voltage N/A 4.2 A N/A 4.2 A N/A 5.0 A N/A 5.8 A N/A 5.8 A
Current at 208 Volt (V) Voltage N/A 2.4 A N/A 2.4 A N/A 2.9 A N/A 3.4 A N/A 3.4 A
Current at 240 Volt (V) Voltage N/A 2.1 A N/A 2.1 A N/A 2.5 A N/A 2.9 A N/A 2.9 A
Resistance N/A 28.8 N/A 28.8 N/A 24.0 N/A 20.6 N/A 20.6
Elements N/A Elements with 0.315"" (8.0 mm) diameters
  • Elements with a 0.315"" diameter are used at 240V or less
  • Manufactured in an extensive range of lengths, wattages, voltages, ratings, and heated length combinations (0.260'' up to 0.625'' diameters).
  • Available in a selection of sheath materials.
  • Terminal box can be added upon request.
  • Cold end lengths can be designed to practically any desired length typically between 40 and 150 mm (1.6""- 5.9""). Elements can be shipped in less than 4 working days.
  • Multiple elements are field wired in series or parallel or star & delta to better suit the requirements of your application.
  • Multiple stages are also available.
  • Custom elements can always be available to better meet your specific needs.
  • For quicker deliveries, please consult the factory.
  • Tubular elements can achieve extremely high temperatures and can be dangerous if improperly selected and applied.
Additional Information N/A When ordering, please specify the following:
  • Quantity
  • Catalogue no.
  • Voltage
  • Wattage
  • Cold end length
  • Terminal type
  • Operating temperature and controls
  • Sheath type