Items |
![]() QFD0010 1 Kilowatts (kW) Power QFD Flanged Air Duct Heater with Finned Elements |
![]() QFD0025 2.5 Kilowatts (kW) Power QFD Flanged Air Duct Heater with Finned Elements |
![]() QFD0075 7.5 Kilowatts (kW) Power QFD Flanged Air Duct Heater with Finned Elements |
![]() QFD0100 10 Kilowatts (kW) Power QFD Flanged Air Duct Heater with Finned Elements |
![]() QFD0125 12.5 Kilowatts (kW) Power QFD Flanged Air Duct Heater with Finned Elements |
|||||
Description |
N/A
|
|||||||||
Brands | N/A WATTCO™ | |||||||||
Power | N/A 1.0 kW | N/A 2.5 kW | N/A 7.5 kW | N/A 10.0 kW | N/A 12.5 kW | |||||
Phase | N/A 1 | N/A 1 3 | N/A 1 3 | N/A 1 3 | N/A 1 3 | |||||
Standard Voltage at Single Phase | N/A 120 V208 V | N/A 120 V208 V | N/A 208 V480 V | N/A 208 V480 V | N/A 208 V480 V | |||||
Standard Voltage at Three Phase | N/A | N/A 240 V | N/A 240 V600 V | N/A 240 V600 V | N/A 240 V600 V | |||||
Dimension A | N/A 6 in152 mm | N/A 6 in152 mm | N/A 14 in356 mm | N/A 14 in356 mm | N/A 16 in406 mm | |||||
Dimension B | N/A 6 in152 mm | N/A 6 in152 mm | N/A 8 in203 mm | N/A 12 in305 mm | N/A 12 in305 mm | |||||
Dimension C | N/A 6 1/2 in163 mm | |||||||||
Dimension D | N/A 7 in178 mm | |||||||||
Dimension E | N/A 2 in51 mm | |||||||||
Minimum Air Flow | N/A 50 ft³/min1.4 m³/min | N/A 150 ft³/min4.2 m³/min | N/A 390 ft³/min11.0 m³/min | N/A 500 ft³/min14.1 m³/min | N/A 625 ft³/min17.7 m³/min | |||||
Number of Finned Elements | N/A 2 | N/A 3 | N/A 4 | N/A 6 | N/A 6 | |||||
Approximate Weight | N/A 15 lb7 kg | N/A 15 lb7 kg | N/A 20 lb9 kg | N/A 25 lb11 kg | N/A 30 lb14 kg | |||||
Frame Construction Type | N/A Flanged Duct | |||||||||
Tubular Elements | N/A Finned | |||||||||
Heater Type | N/A QFD | |||||||||
Primary Linear Cutout Temperature | N/A 160 ºC71 ºF | |||||||||
Primary Linear Cutout Alternating Current (AC) Voltage | N/A 277 V600 V | |||||||||
Primary Linear Cutout Current | N/A 10 A25 A | |||||||||
Primer Linear Cutout Type | N/A Non-Inductive | |||||||||
Secondary Linear Cutout Temperature | N/A 107 ºC225 ºF | |||||||||
Secondary Linear Cutout Alternating Current (AC) Voltage | N/A 277 V600 V | |||||||||
Secondary Linear Cutout Current | N/A 10 A25 A | |||||||||
Secondary Linear Cutout Type | N/A Non-Inductive | |||||||||
Alternative Auxiliary Duct Heater Controls |
N/A
The following controls are supplied by WATTCO™ on the duct heater or are available as an EEMAC rated control panel for wall mount:
|
|||||||||
Application | N/A Comfort Heating | |||||||||
Note |
N/A
Units are only examples. For safety reasons, refer to this as a guideline for custom design orders. Custom designed units will be built according to the requirements of your specific application. QFE and QIE Incoloy® tubular duct heaters are only available upon request. |
|||||||||
|