Items |
![]() FLC36100X1426 WATTCO™ 100 Kilowatt (kW) Power Copper Sheath Material High Density 10 Inch (in) Flange Size Immersion Heater |
![]() FLC36140X1432 WATTCO™ 140 Kilowatt (kW) Power Copper Sheath Material High Density 10 Inch (in) Flange Size Immersion Heater |
![]() FLC36160X1435 WATTCO™ 160 Kilowatt (kW) Power Copper Sheath Material High Density 10 Inch (in) Flange Size Immersion Heater |
![]() FLC36200X1442 WATTCO™ 200 Kilowatt (kW) Power Copper Sheath Material High Density 10 Inch (in) Flange Size Immersion Heater |
![]() FLC48240X1435 WATTCO™ 240 Kilowatt (kW) Power Copper Sheath Material High Density 10 Inch (in) Flange Size Immersion Heater |
|||||
Description |
N/A
10" - 3" Cold Section - 150 lb. Steel Flange. Without Thermostat. |
|||||||||
Brands | N/A WATTCO™ | |||||||||
Flange Size | N/A 10 in | |||||||||
Flange Rating | N/A 150 lb | |||||||||
Dimension A | N/A 8 in | |||||||||
Dimension C | N/A 14 1/4 in | |||||||||
Dimension D | N/A 16 in | |||||||||
Dimension E | N/A 12 in | |||||||||
Dimension F | N/A 1 in | |||||||||
Dimension G | N/A 1 3/16 in | |||||||||
Dimension H | N/A 10 in | |||||||||
Power | N/A 100 kW | N/A 140 kW | N/A 160 kW | N/A 200 kW | N/A 240 kW | |||||
Immersion Length B | N/A 660 mm26 in | N/A 813 mm32 in | N/A 889 mm35 in | N/A 1067 mm42 in | N/A 991 mm39 in | |||||
Phase | N/A 1 3 | |||||||||
Voltage | N/A 208 V240 V480 V600 V | |||||||||
Power Density | N/A 64.3 W/in² | N/A 65.4 W/in² | N/A 65.8 W/in² | N/A 64.3 W/in² | N/A 63.8 W/in² | |||||
Approximate Net Weight | N/A 79 lb | N/A 82 lb | N/A 84 lb | N/A 92 lb | N/A 95 lb | |||||
Sheath Material | N/A Copper | |||||||||
Flange Material | N/A Steel | |||||||||
Cold Section | N/A 3 in | |||||||||
Approximate Power Density | N/A 65 W/in² | |||||||||
Power Density Type | N/A High | |||||||||
Moisture Resistant K | N/A 9 in | |||||||||
Moisture Resistant L | N/A 14 3/4 in | |||||||||
Explosion Resistant K | N/A 10 1/8 in | |||||||||
Explosion Resistant L | N/A 13 1/2 in | |||||||||
Heater Type | N/A FLC | |||||||||
Application | N/A Clean Water Freeze Protection Hot Water Storage Boiler and Water Heaters Cooling Towers Solutions not Corrosive to Copper | |||||||||
Note |
N/A
When ordering, please specify: quantity, catalogue number, voltage, phase, wattage, material to be heated, flowing or static mediums, types of controls to be applied, type of metal or alloy of the container, any extra features. Customers must always advise if flange immersion heaters are for steam pressured applications. |
|||||||||
|