Items |
![]() FLC60250X1834 WATTCO™ 250 Kilowatt (kW) Power Copper Sheath Material High Density 14 Inch (in) Flange Size Immersion Heater |
![]() FLC60300X1838 WATTCO™ 300 Kilowatt (kW) Power Copper Sheath Material High Density 14 Inch (in) Flange Size Immersion Heater |
![]() FLC60350X1843 WATTCO™ 350 Kilowatt (kW) Power Copper Sheath Material High Density 14 Inch (in) Flange Size Immersion Heater |
![]() FLC60400X1848 WATTCO™ 400 Kilowatt (kW) Power Copper Sheath Material High Density 14 Inch (in) Flange Size Immersion Heater |
![]() FLC84500X1844 WATTCO™ 500 Kilowatt (kW) Power Copper Sheath Material High Density 14 Inch (in) Flange Size Immersion Heater |
|||||
Description |
N/A
14" - 3" Cold Section - 150 lb. Steel Flange. Without Thermostat. |
|||||||||
Brands | N/A WATTCO™ | |||||||||
Flange Size | N/A 14 in | |||||||||
Flange Rating | N/A 150 lb | |||||||||
Dimension A | N/A 8 in | |||||||||
Dimension C | N/A 18 3/4 in | |||||||||
Dimension D | N/A 21 in | |||||||||
Dimension E | N/A 12 in | |||||||||
Dimension F | N/A 1 1/8 in | |||||||||
Dimension G | N/A 1 3/8 in | |||||||||
Dimension H | N/A 9 3/4 in | |||||||||
Power | N/A 250 kW | N/A 300 kW | N/A 350 kW | N/A 400 kW | N/A 500 kW | |||||
Immersion Length B | N/A 864 mm34 in | N/A 965 mm38 in | N/A 1092 mm43 in | N/A 1219 mm48 in | N/A 1118 mm44 in | |||||
Phase | N/A 1 3 | |||||||||
Voltage | N/A 208 V240 V480 V600 V | |||||||||
Power Density | N/A 63.6 W/in² | N/A 65.5 W/in² | N/A 64.9 W/in² | N/A 64.5 W/in² | N/A 64.3 W/in² | |||||
Approximate Net Weight | N/A 130 lb | N/A 150 lb | N/A 150 lb | N/A 150 lb | N/A 170 lb | |||||
Sheath Material | N/A Copper | |||||||||
Flange Material | N/A Steel | |||||||||
Cold Section | N/A 3 in | |||||||||
Approximate Power Density | N/A 65 W/in² | |||||||||
Power Density Type | N/A High | |||||||||
Moisture Resistant K | N/A 9 in | |||||||||
Moisture Resistant L | N/A 18 3/4 in | |||||||||
Explosion Resistant K | N/A 10 1/8 in | |||||||||
Explosion Resistant L | N/A 17 1/2 in | |||||||||
Application | N/A Clean Water Freeze Protection Hot Water Storage Boiler and Water Heaters Cooling Towers Solutions not Corrosive to Copper | |||||||||
Note |
N/A
When ordering, please specify: quantity, catalogue number, voltage, phase, wattage, material to be heated, flowing or static mediums, types of controls to be applied, type of metal or alloy of the container, any extra features. Customers must always advise if flange immersion heaters are for steam pressured applications. |
|||||||||
|