Items |
![]() FLC1850X1223 WATTCO™ 50 Kilowatt (kW) Power Copper Sheath Material High Density 8 Inch (in) Flange Size Immersion Heater |
![]() FLC1870X1229 WATTCO™ 70 Kilowatt (kW) Power Copper Sheath Material High Density 8 Inch (in) Flange Size Immersion Heater |
![]() FLC1890X1235 WATTCO™ 90 Kilowatt (kW) Power Copper Sheath Material High Density 8 Inch (in) Flange Size Immersion Heater |
![]() FLC18110X1241 WATTCO™ 110 Kilowatt (kW) Power Copper Sheath Material High Density 8 Inch (in) Flange Size Immersion Heater |
![]() FLC18120X1244 WATTCO™ 120 Kilowatt (kW) Power Copper Sheath Material High Density 8 Inch (in) Flange Size Immersion Heater |
|||||
Description |
N/A
8" - 3" Cold Section - 150 lb. Steel Flange. Without Thermostat. |
|||||||||
Brands | N/A WATTCO™ | |||||||||
Flange Size | N/A 8 in | |||||||||
Flange Rating | N/A 150 lb | |||||||||
Dimension A | N/A 5 in | |||||||||
Dimension C | N/A 11 3/4 in | |||||||||
Dimension D | N/A 13 1/2 in | |||||||||
Dimension E | N/A 8 in | |||||||||
Dimension F | N/A 7/8 in | |||||||||
Dimension G | N/A 1 1/8 in | |||||||||
Dimension H | N/A 6 3/4 in | |||||||||
Power | N/A 50 kW | N/A 70 kW | N/A 90 kW | N/A 110 kW | N/A 120 kW | |||||
Immersion Length B | N/A 584 mm23 in | N/A 737 mm29 in | N/A 889 mm35 in | N/A 1041 mm41 in | N/A 1118 mm44 in | |||||
Phase | N/A 1 3 | |||||||||
Voltage | N/A 208 V240 V480 V600 V | |||||||||
Power Density | N/A 63.3 W/in² | N/A 64.7 W/in² | N/A 65.5 W/in² | N/A 66.0 W/in² | N/A 66.2 W/in² | |||||
Approximate Net Weight | N/A 79 lb | N/A 82 lb | N/A 84 lb | N/A 86 lb | N/A 92 lb | |||||
Sheath Material | N/A Copper | |||||||||
Flange Material | N/A Steel | |||||||||
Cold Section | N/A 3 in | |||||||||
Approximate Power Density | N/A 65 W/in² | |||||||||
Power Density Type | N/A High | |||||||||
Moisture Resistant K | N/A 9 in | |||||||||
Moisture Resistant L | N/A 12 1/8 in | |||||||||
Explosion Resistant K | N/A 8 1/8 in | |||||||||
Explosion Resistant L | N/A 11 in | |||||||||
Heater Type | N/A FLC | |||||||||
Application | N/A Clean Water Freeze Protection Hot Water Storage Boiler and Water Heaters Cooling Towers Solutions not Corrosive to Copper | |||||||||
Note |
N/A
When ordering, please specify: quantity, catalogue number, voltage, phase, wattage, material to be heated, flowing or static mediums, types of controls to be applied, type of metal or alloy of the container, any extra features. Customers must always advise if flange immersion heaters are for steam pressured applications. |
|||||||||
|